AirCom
y t f l

Protect-Air

Service


Order Hotline

Telefon +49 2102 7339021

Payment methods

R450

Your are now in the overview of an article: R450
Choose a version from the table underneath, please.

Description:
The volume booster amplifies the volume at a 1 to 1 ratio of
pilot pressure to outlet pressure. The pilot pressure has no
constant bleed and shows the same function as a spring in a
common regulator, generating counter pressure on the diaphragm.
This force is compensated by the outlet pressure on the
diaphragm's bottom side. The ratio of pilot pressure to outlet
pressure depends on the size of the operating diaphragms.

Media: compressed air or non-corrosive gases
Supply_pressure: max. 17 bar

Pilot_pressure: max. 10 bar at 1:1, 2:1 and 3:1 ratio, 5 bar at 1:2, 3.3 bar at 1:3,
Pilot_port: G1/4

Accuracy: at supply pressure variation of 7 bar = < 7 mbar pressure deviation
Response_sensitivity: 2.5 mbar
Air_consumption: without constant bleed
Relieving_function: relieving
Relief_capacity: 1100 l/min at 0.35 bar overpressure above setpoint
Gauge_port: G1/4 on both sides of the body, screw plugs supplied
Mounting_position: any

Temperature_range:
0 °C to 90 °C / 32 °F to 194 °F,
for appropriately conditioned compressed air down to -40 °C/-40 °F

Body: aluminium die-cast
Elastomer: NBR/Buna-N,optionally FKM
Inner_valve: brass and aluminium

Cart

Products:
0 Pieces
Total:
0,00 €

Leaflet

Products:
0 Pieces
Total:
0,00 €

Direct Order

Login

Protection Components