1
The volume booster amplifies the volume at a 1 to 1 ratio of pilot pressure to outlet pressure.
The pilot pressure has no constant bleed and shows the same
function as a spring in a common regulator. Generating counter
pressure on the diaphragm.
Media: compressed air or non-corrosive gases
Supply pressure: max. 17 bar
Pilot port: G1/4
Accuracy:
at supply pressure variation of 7 bar = < 7 mbar pressure deviation
Transmission error:
1% from 1 to 1 to 1 to 3 ratio, 2% at greater or inverse transmission
Response sensitivity:
1 mbar at 1 to 1, 2 mbar at 1 to 2,
3 mbar at 1 to 3 and at inverse transmission
Air consumption: max. 3 l/min, subject to outlet pressure
Relieving function: relieving
Relief capacity: 310 l/min at 1.5 bar outlet and 0.35 bar overpressure above setpoint
Gauge port: G1/4 on both sides of the body, screw plugs supplied
Mounting position: any
Temperature range:
0 °C to 80 °C / 32 °F to 176 °F, NBR,
for appropriately conditioned compr. air down to -40 °C / -40 °F
0 °C to 90 °C / 32 °F to 194 °F, FKM,
for appropriately conditioned compr. air down to -40 °C / -40 °F
Body: aluminium die-cast
Elastomer: NBR/Buna-N, optionally FKM
Inner valve: brass and zinc-plated steel
The pilot pressure has no constant bleed and shows the same
function as a spring in a common regulator. Generating counter
pressure on the diaphragm.
Media: compressed air or non-corrosive gases
Supply pressure: max. 17 bar
Pilot port: G1/4
Accuracy:
at supply pressure variation of 7 bar = < 7 mbar pressure deviation
Transmission error:
1% from 1 to 1 to 1 to 3 ratio, 2% at greater or inverse transmission
Response sensitivity:
1 mbar at 1 to 1, 2 mbar at 1 to 2,
3 mbar at 1 to 3 and at inverse transmission
Air consumption: max. 3 l/min, subject to outlet pressure
Relieving function: relieving
Relief capacity: 310 l/min at 1.5 bar outlet and 0.35 bar overpressure above setpoint
Gauge port: G1/4 on both sides of the body, screw plugs supplied
Mounting position: any
Temperature range:
0 °C to 80 °C / 32 °F to 176 °F, NBR,
for appropriately conditioned compr. air down to -40 °C / -40 °F
0 °C to 90 °C / 32 °F to 194 °F, FKM,
for appropriately conditioned compr. air down to -40 °C / -40 °F
Body: aluminium die-cast
Elastomer: NBR/Buna-N, optionally FKM
Inner valve: brass and zinc-plated steel
Your are now in the overview of an article: R208
Choose a version from the table underneath, please.
part number | connection thread | connection | pressure range [bar] | flow rate air [Nl/min] | Kv [m³/h] | pilot pressure [bar] | transmission ratio | Price |
---|---|---|---|---|---|---|---|---|
R208-02I | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 10 | 1:1 | 425,36 € |
R208-02K | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 5,0 | 1:2 | 464,10 € |
R208-02L | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 3,3 | 1:3 | 464,10 € |
R208-02M | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 2,5 | 1:4 | 586,85 € |
R208-02N | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 2,0 | 1:5 | 586,85 € |
R208-02O | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 1,7 | 1:6 | 586,85 € |
R208-02R | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 10 | 2:1 | 464,10 € |
R208-02S | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 10 | 3:1 | 464,10 € |
R208-02T | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 10 | 4:1 | 586,85 € |
R208-02U | G1/4 | G1/4 | 0...10 | 1300 | 0,7 | max. 10 | 5:1 | 586,85 € |