AirCom
y t f l

Protect-Air

Service


Order Hotline

Telefon +49 2102 7339021

Payment methods

R200

1
The volume booster amplifies the volume at a 1 to 1 ratio of
pilot pressure to outlet pressure.
The pilot pressure has no constant bleed. The bias spring at
booster R200 generates a positive shift of the pressure range
between pilot pressure and outlet pressure.


Media: compressed air or non-corrosive gases
Supply pressure: max. 17 bar
Pilot pressure: max. 10 bar
Pilot port: G1/4

Accuracy: at supply pressure variation of 7 bar = < 20 mbar pressure deviation
Response sensitivity: 30 mbar

Air consumption: without constant bleed
Relieving function: relieving, optionally non-relieving

Relief capacity:
1800 l/min at 0.3 bar overpressure above setpoint


Gauge port: G1/4 on both sides of the body
Mounting position: any

Temperature range:
0 °C to 90 °C / 32 °F to 194 °F,
for appropriately conditioned compressed air down to -40 °C / -40 °F

Body: aluminium die-cast
Elastomer: NBR/Buna-N on Dacron, optionally FKM
Inner valve: stainless steel, cadmium-plated steel and brass

Your are now in the overview of an article: R200
Choose a version from the table underneath, please.

part numberconnection threadconnectionsupply pressure max. [bar]pressure range [bar]flow rate air [Nl/min]Kv [m³/h]transmission ratioPrice
R200-08I G1G1170...102800011,41:12401,77 €
R200-12I G11/2G11/2170...103000012,21:12401,77 €

Cart