Protect-Air
AirCom -
Service
Order Hotline
+49 2102 7339021Payment methods
R03-J
1
Pilot-operated volume booster with positive bias designed to supply
outlet pressure equal to signal pressure plus an adjustable preset
spring constant. With very high forward and reverse flow characteristics
and excellent sensitivity. A typical application is balancing
or regulating pressure in tanks.
Media: oil-free and 5 µm filtered compressed air or non-corrosive gases
Supply pressure: max. 16 bar
Ratio: 1:1
Pilot pressure:
max. 10 bar, accordingly lower in the case of manual pre-pressure setting,
pilot port G1/8
Accuracy:
at supply pressure change from 2 bar to 7 bar
= < 6 mbar pressure deviation
at flow rate change from 0 l/min to 20 l/min
= < 20 mbar pressure deviation
response sensitivity = < 2 mbar
Air consumption:
1.5 l/min at P1= 5 bar,
2 l/min at P1= 7 bar,
4 l/min at P1= 10 bar, < 1% of volume flow
Relieving function: relieving, tapped exhaust
Relief capacity: 700 l/min at 6 bar outlet and 0.35 bar overpressure above setpoint
Gauge port: G1/4 on both sides of the body, one screw plug supplied
Mounting position: any
Temperature range:
0 °C to 60 °C / 32 °F to 140 °F, for appropriately conditioned compressed air down to -30 °C / -22 °F
Body: zinc die-cast
Elastomer: NBR/Buna-N
outlet pressure equal to signal pressure plus an adjustable preset
spring constant. With very high forward and reverse flow characteristics
and excellent sensitivity. A typical application is balancing
or regulating pressure in tanks.
Media: oil-free and 5 µm filtered compressed air or non-corrosive gases
Supply pressure: max. 16 bar
Ratio: 1:1
Pilot pressure:
max. 10 bar, accordingly lower in the case of manual pre-pressure setting,
pilot port G1/8
Accuracy:
at supply pressure change from 2 bar to 7 bar
= < 6 mbar pressure deviation
at flow rate change from 0 l/min to 20 l/min
= < 20 mbar pressure deviation
response sensitivity = < 2 mbar
Air consumption:
1.5 l/min at P1= 5 bar,
2 l/min at P1= 7 bar,
4 l/min at P1= 10 bar, < 1% of volume flow
Relieving function: relieving, tapped exhaust
Relief capacity: 700 l/min at 6 bar outlet and 0.35 bar overpressure above setpoint
Gauge port: G1/4 on both sides of the body, one screw plug supplied
Mounting position: any
Temperature range:
0 °C to 60 °C / 32 °F to 140 °F, for appropriately conditioned compressed air down to -30 °C / -22 °F
Body: zinc die-cast
Elastomer: NBR/Buna-N
Your are now in the overview of an article: R03-J
Choose a version from the table underneath, please.
part number | connection thread | connection | supply pressure max. [bar] | pressure range [bar] | flow rate air [Nl/min] | Kv [m³/h] | Price | |
---|---|---|---|---|---|---|---|---|
R03-02J | G1/4 | G1/4 | 16 | 0,05...10 | 3300 | 2,0 | 282,66 € | |
R03-03J | G3/8 | G3/8 | 16 | 0,05...10 | 3800 | 2,3 | 282,66 € | |
R03-04J | G1/2 | G1/2 | 16 | 0,05...10 | 4500 | 2,7 | 282,66 € | |
R03-02J1 | G1/4 | G1/4 | 16 | 0,05...10 | 3300 | 2,0 | 0...1 | 335,27 € |
R03-03J1 | G3/8 | G3/8 | 16 | 0,05...10 | 3800 | 2,3 | 0...1 | 335,27 € |
R03-04J1 | G1/2 | G1/2 | 16 | 0,05...10 | 4500 | 2,7 | 0...1 | 335,27 € |
R03-02J6 | G1/4 | G1/4 | 16 | 0,05...10 | 3300 | 2,0 | 0...6 | 374,64 € |
R03-03J6 | G3/8 | G3/8 | 16 | 0,05...10 | 3800 | 2,3 | 0...6 | 374,64 € |
R03-04J6 | G1/2 | G1/2 | 16 | 0,05...10 | 4500 | 2,7 | 0...6 | 374,64 € |
Cart
Products:
0 Pieces
Total:
0,00 €
Leaflet
Products:
0 Pieces
Total:
0,00 €