AirCom
y t f l

Protect-Air

Service


Order Hotline

Telefon +49 2102 7339021

Payment methods

V04

1
When these valves reach a certain precalibrated vacuum degree,
they introduce atmospheric air into the circuit to prevent the
increase of the set value and keep it constant.

Application:
They are used as safety valves on non-commissioned tanks or
containers at high vacuum level and on vacuum cup lifting systems.

Media: compressed air or non-corrosive gases

Adjustment: by rotating the spindle with lock nut in both directions


Mounting position: any

Temperature range -20 °C to 80 °C / -4 °F to 176 °F

Body: nickel-plated brass
Inner valve: spring steel and brass
Elastomer: NBR/Buna-N

Your are now in the overview of an article: V04
Choose a version from the table underneath, please.

part numberconnection threadconnectionflow rate air [Nl/min]vacuum range [bar]Price
V04-01 G1/8G1/860-1...-0,329,85 €
V04-04 G1/2G1/2330-1...-0,362,30 €
V04-06 G3/4G3/4660-1...-0,369,16 €
V04-08 G1G11100-1...-0,387,67 €