Protect-Air
AirCom -
Service
Order Hotline
+49 2102 7339021Payment methods
PF
12
The pneumatic proportional regulator controls the outlet pressure in proportion to an electrical command input signal. It
comprises a complete closed loop servo system in a compact mono block assembly with proportional solenoid valve,
electronic regulator and internal pressure transducer. The valve works as a slide valve and is designed for flow
applications such as thermal cutting. The digital control system offers advantages at installation and commissioning for
adapting the valve to special applications. The regulator can be set and optimised using a PC, PR adapter and
software. Data record can be saved and used for further valves. The valve has a constant bleed. At absence of input
signal or supply voltage the valve exhausts.
Software Display: signal, outlet pressure, PID parameters, pressure switch signal etc.
Scope function: view setpoint, outlet pressure, internal signals from PID control
Media: dry, lubricated, unlubricated and 50 μm filtered compressed air or non-corrosive gases
Supply voltage: 24 V DC ± 10 V, residual ripple < 10%
Power consumption: 14 W (810mA current consumption)
Signal range: 0-10 V, 100 kΩ impedance 0/4-20 mA, 250 Ω impedance
Electr. connectio:n plug M12x1, 5-pin (protection class IP65)
Mounting position: any, preferably solenoid on top
Accuracy: hysteresis 0.5% FS
Linearity repeatability: < ± 0.5% FS
Temp. range: fluid / ambient 0 °C to 60 °C / 32 °F to 140 °F
Body: aluminium
Elastomer: NBR/Buna-N
comprises a complete closed loop servo system in a compact mono block assembly with proportional solenoid valve,
electronic regulator and internal pressure transducer. The valve works as a slide valve and is designed for flow
applications such as thermal cutting. The digital control system offers advantages at installation and commissioning for
adapting the valve to special applications. The regulator can be set and optimised using a PC, PR adapter and
software. Data record can be saved and used for further valves. The valve has a constant bleed. At absence of input
signal or supply voltage the valve exhausts.
Software Display: signal, outlet pressure, PID parameters, pressure switch signal etc.
Scope function: view setpoint, outlet pressure, internal signals from PID control
Media: dry, lubricated, unlubricated and 50 μm filtered compressed air or non-corrosive gases
Supply voltage: 24 V DC ± 10 V, residual ripple < 10%
Power consumption: 14 W (810mA current consumption)
Signal range: 0-10 V, 100 kΩ impedance 0/4-20 mA, 250 Ω impedance
Electr. connectio:n plug M12x1, 5-pin (protection class IP65)
Mounting position: any, preferably solenoid on top
Accuracy: hysteresis 0.5% FS
Linearity repeatability: < ± 0.5% FS
Temp. range: fluid / ambient 0 °C to 60 °C / 32 °F to 140 °F
Body: aluminium
Elastomer: NBR/Buna-N
Your are now in the overview of an article: PF
Choose a version from the table underneath, please.
part number | connection thread | connection | supply pressure max. [bar] | pressure range [bar] | flow rate air [Nl/min] | Kv [m³/h] | nominal size | Price |
---|---|---|---|---|---|---|---|---|
PF000-0600 | G3/8 | G3/8 | 12 | 0...6 | 1700 | 1,45 | 8 | 2649,30 € |
PF000-1000 | G3/8 | G3/8 | 18 | 0...10 | 1700 | 1,45 | 8 | 2649,30 € |
PF000-1600 | G3/8 | G3/8 | 18 | 0...16 | 1700 | 1,45 | 8 | 2649,30 € |
PF000-2000 | G3/8 | G3/8 | 22 | 0...20 | 1700 | 1,45 | 8 | 2649,30 € |
PF000-3000 | G3/8 | G3/8 | 40 | 0...30 | 1700 | 1,45 | 8 | 2649,30 € |
PF000-4000 | G3/8 | G3/8 | 50 | 0...40 | 1700 | 1,45 | 8 | 2649,30 € |
PF000-5000 | G3/8 | G3/8 | 60 | 0...50 | 1700 | 1,45 | 8 | 2649,30 € |