AirCom
y t f l

Protect-Air

Service


Order Hotline

Telefon +49 2102 7339021

Payment methods

D9

1
The operating pressure is converted into a proportional, electrical
signal by a silicon pressure transducer. After amplification, the signal
is monitored as an analogue voltage or current signal.

Media: all media compatible with stainless steel 316L, material no. 1.4404
Supply_voltage 12…32 V DC, residual ripple 5%,
reverse voltage protection, max. current consumption 4 mA

Electrical connection: plug M12x1, 4-pins, with coupling socket
Outlet signal:
4…20 mA = max. power consumption 260 mW
0…10 V = max. power consumption 50 mW

Linearity/Hysteresis: < 0.1 % FS typ.; < 0.3 % FS
Repeatability: < 0.1 % FS typ.; < 0.3 % FS
Long-term stability: < 0.1 % FS typ.; < 0.3 % FS

Temperature sensitivity:
< 0.03% FS typical per °C / K
< 0.05% FS typical per °C / K
at 0 °C to 70 °C / 32 °F to 158 °F

Response time: 5 ms at 10…90% of measuring range
Shock resistance: 50 g (11 ms)
Vibration sensitivity: 10 g at 5…500 Hz
Protection class: IP 67 according to DIN EN60529
Mounting position: any

Temperature range: -20 °C to 85 °C / -13 °F to 185 °F

Body/Diaphragm: stainless steel 316L, material no. 1.4404

Your are now in the overview of an article: D9
Choose a version from the table underneath, please.

part numberconnection threadconnectionoverpressure max. [bar]head diameter [mm]pressure range [bar]pressure range [mbar]output signal [mA]output signal [V]Price
D9V-10 G1/8G1/820220...10--0-10249,60 €