AirCom
y t f l

Protect-Air

Service


Order Hotline

Telefon +49 2102 7339021

Payment methods

D7

1
The operating pressure is converted into a proportional, electrical
signal by a ceramics pressure transducer. After amplification, the signal
is monitored as an analogue voltage or current signal.

Media: all non-corrosive media compatible with stainless steel, nylon,
silicon, silicone and epoxy

Supply voltage: 12…32 V DC, residual ripple 5%,
with reverse voltage protection, max. current consumption 4 mA

Electrical connector: plug M12x1, 4-pin, with coupling socket
Protection class: IP67 according to DIN EN60529
Output signal:
4…20 mA = max. power consumption 260 mW
0…10 V = max. power consumption 50 mW

Linearity/Hysteresis: < 0.2 % FS typ.; < 0.5 % FS
Repeatability: < 0.2 % FS typ.; < 0.3 % FS
Long-term stability: < 0.5 % FS typ.; < 1 % FS
Temperature sensitivity: < 0.03% FS typ./°C; < 0.08% FS/°C (0…50 °C)
Vibration resistance: 2 g at 5…500 Hz

Temperature range: -25 °C to 85 °C / -13 °F to 185 °F

Response time: 5 ms for 10…90% of pressure range
Shock resistance: 50 g (11ms)

Body: stainless steel 316L, mat. no. 1.4404
Measuring cell: silicone and NBR/Buna-N o-ring

Your are now in the overview of an article: D7
Choose a version from the table underneath, please.

part numberconnection threadconnectionoverpressure max. [bar]head diameter [mm]pressure range [bar]pressure range [mbar]output signal [mA]output signal [V]Price
D7A-B1 G1/8G1/80,2522-0...104-20-262,08 €
D7V-C6 G1/8G1/8122-0...600-0-100,00 €