Protect-Air
AirCom -
Service
Order Hotline
+49 2102 7339021Payment methods
AP
1
The air amplifier compresses air or nitrogen from a standard
pressure of 10 bar max. to the desired outlet pressure
of 40 bar max. This is realised by cylinders with different
ratios - simple, safe and economical. No electrical installation
is required and there is no energy consumption once the final
pressure has been reached. Service life 3 million cycles, full
load operation 12 min max. per hour.
Media: lubricated, unlubricated and 50 µm filtered compressed air or nitrogen
Amplifier station:
The pressure booster has an additional tank, pressure regulator,
filter, gauge, relief valve and switch-on valve. Pressure pulsation
rates are low, air consumption peaks are compensated and the
operating pressure can be adjusted.
Drive pressure PA: system air to drive the air amplifier, 2…10 bar
Supply pressure P1: max. 12 bar, for instance nitrogen or the system air
Outlet pressure P2: amplified outlet or operating pressure of 20 bar to 40 bar maximum
Temperature range: 0 °C to 60 °C / 32 °F to 140 °F
Sound level: max. 79 dB (A)
Body: aluminium
Seals: NBR/Buna-N
Tank: coated steel, SST at AP40-0050
pressure of 10 bar max. to the desired outlet pressure
of 40 bar max. This is realised by cylinders with different
ratios - simple, safe and economical. No electrical installation
is required and there is no energy consumption once the final
pressure has been reached. Service life 3 million cycles, full
load operation 12 min max. per hour.
Media: lubricated, unlubricated and 50 µm filtered compressed air or nitrogen
Amplifier station:
The pressure booster has an additional tank, pressure regulator,
filter, gauge, relief valve and switch-on valve. Pressure pulsation
rates are low, air consumption peaks are compensated and the
operating pressure can be adjusted.
Drive pressure PA: system air to drive the air amplifier, 2…10 bar
Supply pressure P1: max. 12 bar, for instance nitrogen or the system air
Outlet pressure P2: amplified outlet or operating pressure of 20 bar to 40 bar maximum
Temperature range: 0 °C to 60 °C / 32 °F to 140 °F
Sound level: max. 79 dB (A)
Body: aluminium
Seals: NBR/Buna-N
Tank: coated steel, SST at AP40-0050
Your are now in the overview of an article: AP
Choose a version from the table underneath, please.
part number | connection thread | connection | supply pressure max. [bar] | outlet pressure [bar] | flow rate air [Nl/min] | transmission ratio | weight [kg] | bowl capacity [l] | Price |
---|---|---|---|---|---|---|---|---|---|
AP20-0580 | G3/8 | G3/8 | 12 | 20 | 580 | 1:2 | 13 | 3 | 1906,00 € |
AP20-0960 | G1/2 | G1/2 | 12 | 20 | 960 | 1:2 | 16 | 3 | 3126,00 € |
AP20-1200 | G3/4 | G3/4 | 12 | 20 | 1200 | 1:2 | 49 | 40 | 5788,00 € |
AP20-0230 | G1/2 | G1/2 | 12 | 20 | 230 | 1:3 | 58 | 40 | 5049,00 € |
AP40-0050 | G3/8 | G3/8 | 12 | 40 | 50 | 1:4 | 5,3 | 0,8 | 2148,00 € |
AP40-0360 | G1/2 | G1/2 | 12 | 40 | 360 | 1:5 | 45 | 40 | 6707,00 € |
Cart
Products:
0 Pieces
Total:
0,00 €
Leaflet
Products:
0 Pieces
Total:
0,00 €